GC Capillary Columns
GC Capillary Columns
- (1)
- (2)
- (2)
- (20)
- (45)
- (192)
- (236)
- (81)
- (3)
- (75)
- (1)
- (7)
- (29)
- (4)
- (146)
- (125)
- (102)
- (87)
- (7)
- (2)
- (3)
- (2)
- (2)
- (2)
- (1)
- (2)
- (2)
- (2)
- (3)
- (2)
- (78)
- (8)
- (11)
- (4)
- (11)
- (36)
- (2)
- (37)
- (16)
- (10)
- (13)
- (4)
- (78)
- (9)
- (8)
- (17)
- (16)
- (11)
- (2)
- (1)
- (1)
- (14)
- (1)
- (15)
- (2)
- (14)
- (12)
- (27)
- (2)
- (27)
- (1)
- (3)
- (3)
- (2)
- (2)
- (40)
- (5)
- (22)
- (161)
- (45)
- (2)
- (96)
- (70)
- (1)
- (4)
- (1)
- (8)
- (13)
- (11)
- (16)
- (226)
- (51)
- (3)
- (27)
- (76)
- (30)
- (2)
- (4)
- (5)
- (37)
- (13)
Filtered Search Results
Macherey-Nagel™ Optima™ 5 High Performance GC Capillary Column
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Type | High Performance GC Capillary Column |
---|---|
Stationary Phase | Optima™ 5 |
Quantity | 1 Each |
Temperature Range | 340°C |
For Use With (Application) | Gas Chromatography (GC) |
USP Type | G27 |
Macherey-Nagel™ OPTIMA™ 1 GC Capillary Column, 0.8mm O.D.
Designed for separation of components according to boiling points. Macherey-Nagel™ OPTIMA™ 1 GC Capillary Column, 0.8mm O.D. are non-polar phase columns with 100% dimethylpolysiloxane for use in gas chromatography. Available in a range of lengths and film thicknesses.
Type | GC Capillary Column |
---|---|
Stationary Phase | Optima™ 1 |
Diameter (Metric) | 0.8 mm |
Diameter (Metric) Inner | 0.53 mm |
Quantity | 1 Each |
USP Type | G1, G2, G38 |
Macherey-Nagel™ OPTIMA™ δ-3 Capillary Columns for GC
Ideal for MSD and PND detectors. Macherey-Nagel™ OPTIMA™ δ-3 Capillary Columns for GC are polysiloxane phase columns with autoselective polarity. The analytes determine the polarity of the phase. Available in a range of diameters, lengths and film thicknesses.
Type | GC Capillary Column |
---|---|
Stationary Phase | Optima™ d-3 |
For Use With (Equipment) | Ideal for MSD and PND Detectors |
Quantity | 1 Each |
For Use With (Application) | Gas Chromatography (GC) |
USP Type | G49 |
Macherey-Nagel™ OPTIMA™ 624 GC Capillary Column
Recommended for environmental analyses. Macherey-Nagel™ OPTIMA™ 624 GC Capillary Columns are high-performance, medium polar phase columns of 6% cyanopropyl-phenyl and 94% dimethylpolysiloxane for use in gas chromatography. Available in a range of diameters, lengths and film thicknesses.
Type | GC Capillary Column |
---|---|
Stationary Phase | Optima™ 624 |
Quantity | 1 Each |
Temperature Range | 280°C to 300°C |
For Use With (Application) | Gas Chromatography (GC) |
USP Type | G43 |
Macherey-Nagel™ HYDRODEX™ β-PM Capillary Columns for GC
Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ HYDRODEX™ β-PM Capillary Columns for GC are phases with 7 β-cyclodextrin glucose units for enantiomer separation in gas chromatography. This hydrophilic phase with short polar ligants is a chemically non-bonded phase.
Max. Temperature | For isothermal operations: 230°C, For short isotherms in a temperature program: 250°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | Hydrodex β-PM |
Packing Material | Hydrodex β-PM |
Diameter (Metric) | 0.4 mm |
Diameter (Metric) Inner | 0.25 mm |
Quantity | 1 Each |
Polarity | Polar |
For Use With (Application) | Enantiomer Separation |
Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.53mm ID
Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.53mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions.
Max. Temperature | 200°C (long term), 220°C (in temperature program) |
---|---|
Type | GC Capillary Column |
Stationary Phase | Permabond™ CW 20 M |
Packing Material | Poly(ethylene glycol) |
Diameter (Metric) | 0.8 mm |
Diameter (Metric) Inner | 0.53 mm |
Quantity | 1 Each |
Functionality/Interaction Type | Polar phase |
USP Type | G16 |
Type | High Performance GC Capillary Column |
---|---|
Stationary Phase | Optima™ 1 |
Quantity | 1 Each |
USP Type | G1, G2, G38 |
Type | GC Capillary Column |
---|---|
Stationary Phase | Permabond™ CW 20 M-DEG |
Length (Metric) | 25 m |
Packing Material | Permabond™ CW 20 M-DEG |
Quantity | 1 Each |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 0.25 μm |
USP Type | G16 |
Type | GC Column Retention Gap |
---|---|
Quantity | 1 Each |
Temperature Range | 320°C |
Type | GC Capillary Column |
---|---|
Stationary Phase | Optima™ 1 MS Accent |
For Use With (Equipment) | Ideal for Ion Trap and Quadrupole MS Detectors |
Quantity | 1 Each |
Temperature Range | 360°C |
For Use With (Application) | Gas Chromatography (GC) |
USP Type | G1, G2, G38 |
Macherey-Nagel™ LIPODEX™ A Capillary Columns for GC
Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ LIPODEX™ A Capillary Columns for GC are phases with six α-cyclodextrin glucose units for enantiomer separation in gas chromatography. This lipophilic phase with long nonpolar ligants is a chemically non-bonded phase.
Max. Temperature | For isothermal operations: 200°C, For short isotherms in a temperature program: 220°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | Lipodex™ A |
Packing Material | Lipodex™ A |
Diameter (Metric) | 0.4 mm |
Diameter (Metric) Inner | 0.25 mm |
Quantity | 1 Each |
Polarity | Non polar |
For Use With (Application) | Enantiomer Separation |
Macherey-Nagel™ LIPODEX™ G Capillary Columns for GC
Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ LIPODEX™ G Capillary Columns for GC are phases with eight γ-cyclodextrin glucose units for enantiomer separation in gas chromatography. This lipophilic phase with long nonpolar ligants is a chemically non-bonded phase.
Max. Temperature | For isothermal operations: 220°C, For short isotherms in a temperature program: 240°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | Lipodex™ G |
Packing Material | Lipodex™ G |
Diameter (Metric) | 0.4 mm |
Diameter (Metric) Inner | 0.25 mm |
Quantity | 1 Each |
Polarity | Non polar |
For Use With (Application) | Enantiomer Separation |
Macherey-Nagel™ OPTIMA™ 35 MS Capillary Columns for GC
Features ultra-low bleed characteristics with high temperature stability. Macherey-Nagel™ OPTIMA™ 35 MS Capillary Columns for GC are chemically bonded, cross-linked silarylene phase columns with unique selectivity in the mid-polar region and excellent tubing surface deactivation.
Max. Temperature | For isothermal operations: 360°C, Short isotherm in temperature program: 370°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | Optima™ 35 MS |
For Use With (Equipment) | Recommended for Ion Trap Detectors |
Quantity | 1 Each |
For Use With (Application) | PCBs Analysis,Ultra Trace Analyses,EPA Methods,Pesticide Analysis,PCBs,Food and Drug Analysis |
Film Thickness | 0.25 μm |
USP Type | G42 |
Macherey-Nagel™ LIPODEX™ B Capillary Columns for GC
Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ LIPODEX™ B Capillary Columns for GC are phases with six α-cyclodextrin glucose units for enantiomer separation in gas chromatography. This lipophilic phase with long nonpolar ligants is a chemically non-bonded phase.
Max. Temperature | For isothermal operations: 200°C, For short isotherms in a temperature program: 220°C |
---|---|
Type | GC Capillary Column |
Stationary Phase | Lipodex™ B |
Packing Material | Lipodex™ B |
Diameter (Metric) | 0.4 mm |
Diameter (Metric) Inner | 0.25 mm |
Quantity | 1 Each |
Polarity | Non polar |
For Use With (Application) | Enantiomer Separation |
Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.32mm ID
Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.32mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions.
Max. Temperature | 220°C (long term), 240°C (in temperature program) |
---|---|
Type | GC Capillary Column |
Stationary Phase | Permabond™ CW 20 M |
Packing Material | Poly(ethylene glycol) |
Diameter (Metric) | 0.5 mm |
Diameter (Metric) Inner | 0.32 mm |
Quantity | 1 Each |
Functionality/Interaction Type | Polar phase |
USP Type | G16 |